Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 67(18)2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-35981551

RESUMO

Objective.The red bone marrow (RBM) and bone endosteum (BE), which are required for effective dose calculation, are macroscopically modeled in the reference phantoms of the international commission on radiological protection (ICRP) due to their microscopic and complex histology. In the present study, the detailed bone models were developed to simplify the dose calculation process for skeletal dosimetry.Approach.The detailed bone models were developed based on the bone models developed at the University of Florida. A new method was used to update the definition of BE region by storing the BE location indices using virtual sub-voxels. The detailed bone models were then installed in the spongiosa regions of the ICRP mesh-type reference computational phantoms (MRCPs) via the parallel geometry feature of the Geant4 code.Main results.Comparing the results between the detailed-bone-installed MRCPs and the original MRCPs with the absorbed dose to spongiosa and fluence-to-dose response function (DRF)-based methods, the DRF-based method showed much smaller but still significant differences. Compared with the values given in ICRPPublications116 and 133, the differences were very large (i.e. several orders of magnitudes), due mainly to the anatomical improvement of the skeletal system in the MRCPs; that is, spongiosa and medullary cavity are fully enclosed by cortical bone in the MRCPs but not in the ICRP-110 phantoms.Significance.The detailed bone models enable the direct calculation of the absorbed doses to the RBM and BE, simplifying the dose calculation process and potentially improving the consistency and accuracy of skeletal dosimetry.


Assuntos
Proteção Radiológica , Adulto , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Microtomografia por Raio-X
2.
J Radiol Prot ; 42(3)2022 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-35921807

RESUMO

In line with the activities of Task Group 103 under the International Commission on Radiological Protection (ICRP), the present study was conducted to develop a new set of alimentary tract organs consisting of the oral cavity, oesophagus, stomach, small intestine, and colon for the newborn, 1 year-old, 5 year-old, 10 year-old, and 15 year-old males and females for use in the pediatric mesh-type reference computational phantoms (MRCPs). The developed alimentary tract organs of the pediatric MRCPs, while nearly preserving the original topology and shape of those of the pediatric voxel-type reference computational phantoms (VRCPs) of ICRPPublication 143, present considerable anatomical improvement and include all micrometre-scale target and source regions as prescribed in ICRPPublication 100. To investigate the dosimetric impact of the developed alimentary tract organs, organ doses and specific absorbed fractions were computed for certain external exposures to photons and electrons and internal exposures to electrons, respectively, which were then compared with the values computed using the current ICRP models (i.e. pediatric VRCPs and ICRP-100 stylised models). The results showed that for external exposures to penetrating radiations (i.e. photons >0.04 MeV), there was generally good agreement between the compared values, within a 10% difference, except for the oral mucosa. For external exposures to weakly penetrating radiations (i.e. low-energy photons and electrons), there were significant differences, up to a factor of ∼8300, owing to the geometric difference caused by the anatomical enhancement in the MRCPs. For internal exposures of electrons, there were significant differences, the maximum of which reached a factor of ∼73 000. This was attributed not only to the geometric difference but also to the target mass difference caused by the different luminal content mass and organ shape.


Assuntos
Proteção Radiológica , Telas Cirúrgicas , Criança , Pré-Escolar , Simulação por Computador , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos
3.
J Radiol Prot ; 41(2)2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33882468

RESUMO

The International Commission on Radiological Protection (ICRP) recently reduced the dose limit for the eye lens for occupational exposure from 150 mSv yr-1to 20 mSv yr-1, as averaged over defined periods of five years, with no annual dose in a single year exceeding 50 mSv, emphasizing the importance of the accurate estimation of lens dose. In the present study, for more accurate lens dosimetry, detailed eye models were developed for children and adolescents (newborns and 1, 5, 10, and 15 year olds), which were then incorporated into the pediatric mesh-type reference computational phantoms (MRCPs) and used to calculate lens dose coefficients (DCs) for photon and electron exposures. Finally, the calculated values were compared with those calculated with the adult MRCPs in order to determine the age dependence of the lens DCs. For photon exposures, the lens DCs of the pediatric MRCPs showed some sizable differences from those of the adult MRCPs at very low energies (10 and 15 keV), but the differences were all less than 35%, except for the posterior-anterior irradiation geometry, for which the lens dose is not of primary concern. For electron exposures, much larger differences were found. For the anterior-posterior (AP) and isotropic irradiation geometries, the largest differences between the lens DCs of the pediatric and adult phantoms were found in the energy range of 0.6-1 MeV, where the newborn lens DCs were larger by up to a factor of ∼5 than the adult. The lens DCs of the present study, which were calculated for the radiosensitive region of the lens, also were compared with those for the entire lens in the AP irradiation geometry. Our results showed that the DCs of the entire lens were similar to those of the radiosensitive region for 0.02-2 MeV photons and >2 MeV electrons, but that for the other energy ranges, significant differences were noticeable, i.e. 10%-40% for photons and up to a factor of ∼5 for electrons.


Assuntos
Cristalino , Radiometria , Adolescente , Adulto , Criança , Humanos , Recém-Nascido , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Doses de Radiação
4.
J Radiol Prot ; 41(4)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-33647886

RESUMO

For use in electron paramagnetic resonance dosimetry with tooth enamel, in the present study, very detailed mesh-type tooth models composed of 198 individual tooth models (i.e. newborn: 20; 1 year: 28; 5 years: 48; 10 years: 38; 15 years: 32; and adult: 32) were developed for each sex. The developed tooth models were then implanted in the International Commission on Radiological Protection pediatric and adult mesh-type reference computational phantoms and used to calculate tooth enamel doses, by Monte Carlo simulations with Geant4, for external photon exposures in several idealized irradiation geometries. The calculated dose values were then compared to investigate the dependency of the enamel dose on the age and sex of the phantom and the sites of the teeth. The results of the present study generally show that, if the photon energy is low (i.e. <0.1 MeV), the enamel dose is significantly affected by the age and sex of the phantom and also the sites of the teeth used for dose calculation; the differences are frequently greater than a few times or even orders of magnitude. However, with a few exceptions, the enamel dose was hardly affected by these parameters for energies between 0.1 and 3 MeV. For energies >3 MeV, moderate differences were observed (i.e., up to a factor of two), due to the existence of dose build-up in the head of the phantom for high-energy photons. The calculated dose values were also compared with those of the previous studies where voxel and mathematical models were used to calculate the enamel doses. The results again show significant differences at low energies, e.g., up to ∼3500 times at 0.015 MeV, which are mainly due to the differences in the level of tooth-modeling detailedness.


Assuntos
Radiometria , Telas Cirúrgicas , Adulto , Criança , Humanos , Recém-Nascido , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação
5.
J Radiol Prot ; 41(2)2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33401263

RESUMO

In 2016, the International Commission on Radiological Protection (ICRP) launched Task Group 103 (TG 103) for the explicit purpose of developing a new generation of adult and pediatric reference computational phantoms, named 'mesh-type reference computational phantoms (MRCPs)', that can overcome the limitations of voxel-type reference computational phantoms (VRCPs) of ICRPPublications 110and143due to their finite voxel resolutions and the nature of voxel geometry. After completing the development of the adult MRCPs, TG 103 has started the development of pediatric MRCPs comprising 10 phantoms (male and female versions of the reference newborn, 1-year-old, 5-year-old, 10-year-old, and 15-year-old). As part of the TG 103 project, within the present study, the skeletal systems, one of the most important and complex organ systems of the body, were developed for each phantom age and sex. The developed skeletal systems, while closely preserving the original bone topology of the pediatric VRCPs, present substantial improvements in the anatomy of complex and/or small bones. In order to investigate the dosimetric impact of the developed skeletons, the average absorbed doses and the specific absorbed fractions for radiosensitive skeletal tissues (i.e. active marrow and bone endosteum) were computed for some selected external and internal exposure cases, which were then compared with those calculated with the skeletons of pediatric VRCPs. The comparison result showed that the dose values of the pediatric MRCPs were generally similar to those of the pediatric VRCPs for highly penetrating radiations (e.g. photons >200 keV); however, for weakly penetrating radiations (e.g. photons ⩽200 keV and electrons), significant differences up to a factor of 140 were observed.


Assuntos
Proteção Radiológica , Telas Cirúrgicas , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Doses de Radiação , Radiometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...